The Causes of Common Faults in Double Suction Pump and the Way to Eliminate It

Common faults (a): pump is not absorbent, pressure gauge and vacuum gauge pointer violently beating. Failure causes: 1, pump enough water; 2, pipe or instrument leaks. Troubleshooting methods: 1, continue to pump water. 2, tighten the blockage leak. Common Faults (B): Pump does not absorb water, the vacuum gauge shows a high degree of vacuum. Failure causes: 1, the end of the Valve did not open or blocked; 2, the resistance of the suction pipe is too large; 3 absorbent height is too high. Troubleshooting methods; 1, the calibration or replacement of the bottom valve; 2, cleaning or replacement of suction pipes; 3, reducing the height of water absorption; common failures (C): pump water, pressure gauge shows pressure. Fault causes: 1, the outlet pipe resistance is too large; 2, the rotation direction is not correct; 3, night traffic jam; 4, speed is not enough. Troubleshooting methods: 1, reduce or shorten the water outlet pipe; 2, to correct the direction of motor rotation; 3, impeller cleaning; 4, increase speed. Common faults (d): insufficient flow or too low head. Fault causes: 1, the impeller or inlet and outlet pipes blocked; 2, double suction seal ring wear too much, or impeller damage, 3, the speed is lower than the specified value. Troubleshooting methods: 1 clean the impeller or pipe; 2, replace the damaged parts; 3 adjusted to the rated speed. Common Faults (E): The pump consumes too much power. Fault causes: 1 packing pressure is too tight; 2, impeller and double suction seal ring friction; 3, the flow is too large. Troubleshooting methods: 1, loose packing gland; 2, check the reasons to eliminate mechanical friction; 3, reduce the flow. Common faults (f): pump internal sound law field, the pump is not on the water. Fault causes: 1 suction pipe resistance is too large; 2, high water absorption 3, suction out of the air inhalation; 4, the suction liquid temperature is too high; 5, cavitation phenomenon. Troubleshooting methods: clean up the suction pipe and the bottom valve; 2, reducing the height of water absorption; 3, check the bottom valve to reduce the height of water absorption, blockage of air leaks; 4, to reduce the liquid temperature; 5, adjust the outlet valve so that the required performance Range of operation. Common Faults (7): The pump is not normal vibration. Failure causes: 1, pump cavitation; 2, impeller imbalance; 3, the pump shaft and the motor shaft is not the heart; 4, submit the screw loose. Troubleshooting methods: 1, adjust the outlet valve, so that the provisions of the performance within the scope of operation; 2 teach impeller static balance; 3, the correction of pump shaft and motor shaft concentricity; 4, quiet foot screws. Common faults (eight); bearing overheating. Failure causes: 1, there is no oil bearing 2, the pump shaft is not agree with the center line. Troubleshooting methods: 1, plus lubricants; 2 to adjust the two weeks of concentricity and in the same center line, build factories and cleaning the bearing body.

Car Refrigerator

Car Refrigerator,Car Fridge Freezer,Car Freezer,Mini Fridge For Car

LONG TERM ELEC. CO., LTD , https://www.longterm-hvac.com